ULTRA FLAME FIREPLACE GAS INSERT INSTALLATION AND OPERATING INSTRUCTIONS FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAP
- Install the wall switch in a convenient location. Route a proper sized wire from the switch or the thermostat to the gas valve. Distance betwee
20. Install the firebox bottom plate and burner following page 12 instructions. 21. Install the 4 logs on the burner as shown on page 13. 22. I
GLASS FRONT REMOVAL CLEANING AND INSTALLATION : * To remove the glass front, unscrew the six screws holding it in place as shown. CAUTION : Hold
BURNER REMOVAL AND INSTALLATION : REMOVAL : 1. Slide the burner to the left and pull toward you. 2. To gain access to the fan, also remove the fir
LOG INSTALLATION : 1. Remove the glass front as described on page 11. 2. Install the longer log in back of the firebox with locating grooves on to
FACE PLATE ASSEMBLY AND INSTALLATION : ASSEMBLY : 1. Bolt the face plate top piece to the left piece using two #10-24 x 1/2 bolts and nuts (B). 2.
INSTALLATIONS : 1. Screw the air deflector on the unit as shown using three #10 x 1/2 metal screws. 2. Bring the face plate in position on the gas
REFRACTORY PANELS INSTALLATIONS : 1. Remove the front glass as described on page 11. 2. Remove the logs from the firebox. 3. Install the two sid
OPERATING INSTRUCTIONS LIGHTING INSTRUCTIONS : 1. Open the bottom louvers of the face plate to reach the control. 2. Turn the gas valve knob to th
MAINTENANCE INSTRUCTIONS : TURN OFF THE GAS WITH THE SHUTDOWN VALVE AND THE ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. * The venting system and
TABLE OF CONTENTS : GENERAL INFORMATION :... 2 WARNING :...
OPTIONAL PARTS ITEM DESCRIPTION Part No QTY Face plate, silver gray enamel E5422 1 Face plate, black enamel E5420
____________________________ LIMITED 5 YEARS WARRANTY ____________________________ DROLET STOVES AND FIREPLACES INC. hereby warrants the quality of
GENERAL INFORMATION : The ULTRA FLAME is a high efficiency fireplace gas insert with an input rating of 30 000 Btu/h with natural gas and 26 000 Btu/
WARNING * INSTALLATION SHOULD BE DONE BY A QUALIFIED INSTALLER. * DO NOT BURN WOOD OR ANY OTHER MATERIAL IN THE GAS INSERT. * HOT WHEN IN OPERATION.
SPECIFICATIONS : Dimensions : height : 20” width : 28” depth : 15” face plate : 44 5/16” x 27 1/2” glass : 14 1/2
TOP, SIDE AND FRONT VIEWS : 5
INSTALLATION : 1. When the masonry fireplace that will receive the ULTRA FLAME gas insert is thoroughly cold, remove all ashes and vacuum clean. 2.
11. Secure the liner to the 4” connector on the top of the ULTRA FLAME with three metal screws. 12. Push the ULTRA FLAME back in the fireplace whi
13. Install a 1/8” NPT plugged tapping for test gauge connection immediately upstream of the gas supply connection to the appliance. 14. Install a