ULTRA FLAME
FIREPLACE GAS INSERT
INSTALLATION AND OPERATING INSTRUCTIONS
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND
LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
FOR YOUR SAFETY
IF YOU SMELL GAS :
1. OPEN WINDOWS
2. TURN OFF MAIN GAS SUPPLY
3. DON’T TOUCH ELECTRICAL SWITCHES
4. EXTINGUISH ANY OPEN FLAME
5. IMMEDIATELY CALL YOUR GAS SUPPLIER
Tested by :
Manufactured by :
DROLET STOVES & FIREPLACES INC.
1700, Leon-Harmel
Quebec, Qc (Canada)
WARNOCK HERSEY
G1N 4R9
Rev. 07/96 45028A
Vue de la page 0
1 2 3 4 5 6 ... 20 21

Résumé du contenu

Page 1 - ULTRA FLAME

ULTRA FLAME FIREPLACE GAS INSERT INSTALLATION AND OPERATING INSTRUCTIONS FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAP

Page 2

- Install the wall switch in a convenient location. Route a proper sized wire from the switch or the thermostat to the gas valve. Distance betwee

Page 3

20. Install the firebox bottom plate and burner following page 12 instructions. 21. Install the 4 logs on the burner as shown on page 13. 22. I

Page 4

GLASS FRONT REMOVAL CLEANING AND INSTALLATION : * To remove the glass front, unscrew the six screws holding it in place as shown. CAUTION : Hold

Page 5

BURNER REMOVAL AND INSTALLATION : REMOVAL : 1. Slide the burner to the left and pull toward you. 2. To gain access to the fan, also remove the fir

Page 6 - TOP, SIDE AND FRONT VIEWS :

LOG INSTALLATION : 1. Remove the glass front as described on page 11. 2. Install the longer log in back of the firebox with locating grooves on to

Page 7

FACE PLATE ASSEMBLY AND INSTALLATION : ASSEMBLY : 1. Bolt the face plate top piece to the left piece using two #10-24 x 1/2 bolts and nuts (B). 2.

Page 8

INSTALLATIONS : 1. Screw the air deflector on the unit as shown using three #10 x 1/2 metal screws. 2. Bring the face plate in position on the gas

Page 9

REFRACTORY PANELS INSTALLATIONS : 1. Remove the front glass as described on page 11. 2. Remove the logs from the firebox. 3. Install the two sid

Page 10

OPERATING INSTRUCTIONS LIGHTING INSTRUCTIONS : 1. Open the bottom louvers of the face plate to reach the control. 2. Turn the gas valve knob to th

Page 11

MAINTENANCE INSTRUCTIONS : TURN OFF THE GAS WITH THE SHUTDOWN VALVE AND THE ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. * The venting system and

Page 12

TABLE OF CONTENTS : GENERAL INFORMATION :... 2 WARNING :...

Page 13

OPTIONAL PARTS ITEM DESCRIPTION Part No QTY Face plate, silver gray enamel E5422 1 Face plate, black enamel E5420

Page 14

____________________________ LIMITED 5 YEARS WARRANTY ____________________________ DROLET STOVES AND FIREPLACES INC. hereby warrants the quality of

Page 15

GENERAL INFORMATION : The ULTRA FLAME is a high efficiency fireplace gas insert with an input rating of 30 000 Btu/h with natural gas and 26 000 Btu/

Page 16

WARNING * INSTALLATION SHOULD BE DONE BY A QUALIFIED INSTALLER. * DO NOT BURN WOOD OR ANY OTHER MATERIAL IN THE GAS INSERT. * HOT WHEN IN OPERATION.

Page 17

SPECIFICATIONS : Dimensions : height : 20” width : 28” depth : 15” face plate : 44 5/16” x 27 1/2” glass : 14 1/2

Page 18

TOP, SIDE AND FRONT VIEWS : 5

Page 19

INSTALLATION : 1. When the masonry fireplace that will receive the ULTRA FLAME gas insert is thoroughly cold, remove all ashes and vacuum clean. 2.

Page 20

11. Secure the liner to the 4” connector on the top of the ULTRA FLAME with three metal screws. 12. Push the ULTRA FLAME back in the fireplace whi

Page 21

13. Install a 1/8” NPT plugged tapping for test gauge connection immediately upstream of the gas supply connection to the appliance. 14. Install a