READ THESE INSTRUCTIONS AND SAVE FOR REFERENCE 000629/45089A INSTALLATION AND OPERATING MANUAL OIL BURNING STOVE MONT BLANC Vérified and
Page 9 of 15 OPERATION INSTRUCTIONS COMBUSTIBLE • Your appliance has been design to work with oil #1 or #2. DO NOT USE GASOLINE, CRANKCASE OIL
Page 10 of 15 LIGHTING (CONT’D) • Place the flow regulating handle on the "1" position, as soon as the oil has started flowing into th
Page 11 of 15 TURNING THE APPLIANCE OFF • Set the flow regulating handle to position 0. • If you plan to keep the appliance off for a long while
Page 12 of 15 TROUBLESHOOTING GUIDE PROBLEMS CAUSES SOLUTION ON POSITION 6 (MAXIMUM) THE FLAME IS LONGER AND PRODUCES SMOKE, THERE IS
Page 13 of 15 TROUBLESHOOTING GUIDE (CONT’D) PROBLEMS CAUSES SOLUTION THE FLAME PRODUCES SMOKE, IN ANY POSITION Door gasket is not sealed p
Page 14 of 15 SPARE PARTS After years of use, if you need to replace some parts, please contact your SUPPLIER or one of our Drolet approved DEALE
Page 15 of 15 SPARE PARTS (CONT’D) Figure 16: MONT BLANC EXPLODED VIEW, SPARE PARTS LIST
Page 16 of 15 1700, rue Léon-Harmel, Québec (Québec) G1N 4R9 tel. : (418) 527-3060 fax : (418) 527-4311 e-mail : [email protected] web site : dro
Page 1 of 15 TABLE OF CONTENTS TECHNICAL DATA ...
Page 2 of 15 TECHNICAL DATA MONT BLANC OIL BURNING STOVE COMBUSTIBLE : OIL NO 1 OIL NO 2 HEAT INPUT : Kw BTU/h Kw BTU/h Minimum : 5,9 20
Page 3 of 15 INSTALLATION INSTRUCTIONS LOCATING THE APPLIANCE • Position the appliance as close as possible to the chimney. • Many configuratio
Page 4 of 15 CHIMNEY INFORMATIONS • Before the hook up of the appliance, inspect the chimney to ensure that it is in good condition and that the
Page 5 of 15 CONNECTING THE APPLIANCE TO THE CHIMNEY • The gases are vented from the back of the appliance. The female part of the black pipe c
Page 6 of 15 LEVELLING THE APPLIANCE • Now that the appliance is in place and properly hooked up to the chimney, you have to adjust the
Page 7 of 15 CONNECTING APPLIANCE TO OIL TANK • Make sure that the tank outlet is 12" (305 mm) higher than the inlet of the carburetor. (Gr
Page 8 of 15 ADJUSTING THE DRAFT • Your appliance operated with natural draft, created by the ascension of combustion gases in the chimney. Thi