Drolet NG1800 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Poêles Drolet NG1800. Drolet NG1800 User's Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 25
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
OWNER`S MANUAL
DROLET
NG1800 WOODSTOVES:
AUSTRAL, AZIMUTH, BALTIC, LEGEND AND
MYRIAD
US ENVIRONMENTAL PROTECTION
AGENCY PHASE II CERTIFIED
WOODSTOVES
Verified and tested following
ULC S627 and UL 1482 Standards by:
Intertek Testing Services
Manufactured by : STOVE BUILDER INTERNATIONAL INC..
1700, Léon-Harmel, Québec (Québec) G1N 4R9
Tel : (418 ) 527-3060
Fax : (418 ) 527-4311
www.drolet.ca
READ AND KEEP THIS MANUAL FOR REFERENCE
45063A_rev. fev.03.doc
Vue de la page 0
1 2 3 4 5 6 ... 24 25

Résumé du contenu

Page 1 - WOODSTOVES:

OWNER`S MANUAL DROLET NG1800 WOODSTOVES: AUSTRAL, AZIMUTH, BALTIC, LEGEND AND MYRIAD US ENVIRONMENTAL PROTECTION AGENCY PHASE II CERTIFIED W

Page 2 - TABLE OF CONTENTS

CLEARANCES FROM COMBUSTIBLES It is of outmost importance that the clearances to combustible materials be scrupulously respected upon installation of t

Page 3 - INTRODUCTION

10REDUCED CLEARANCES (CANADA ONLY) You may decrease the clearances by installing heat radiation shields between the walls or the ceiling and the stov

Page 4 - TECHNICAL SPECIFICATIONS

11CHIMNEY Your wood stove may be hooked up with a factory built or masonry chimney. If you are using a factory built chimney, it must comply with UL

Page 5 - ASSEMBLY

CHIMNEY CONNECTOR (STOVE PIPE) Your chimney connector and chimney must have the same diameter as the stove outlet. If this is not the case, we recomm

Page 6

TYPICAL INSTALLATIONS FACTORY BUILT CHIMNEY: ROOF FLASHING18" CLEARANCEWALL SUPPORTWALL RADIATION SHIELDRAIN CAP Wall installation CEILING

Page 7 - DOOR ADJUSTMENT

MASONRY CHIMNEY: Clay liner Thimble Clean out door 14

Page 8 - INSTALLATION

FACTORY BUILT THIMBLE: 15

Page 9

BRICK THIMBLE: 16

Page 10 - CLEARANCES FROM COMBUSTIBLES

17OUTSIDE COMBUSTION AIR Your DROLET stove is approved to be installed with an outside air intake which is necessary for a mobile home. This type o

Page 11 - TYPE OF PROTECTION

18WOODSTOVE UTILISATION Your heating unit was designed to burn wood only; no other materials should be burnt. Wastes and other flammable materials s

Page 12 - CHIMNEY

1 TABLE OF CONTENTS INTRODUCTION... 2 T

Page 13

19Smaller pieces of wood will dry faster. All logs exceeding 6" in diameter should be split. The wood should not be stored directly on the gro

Page 14 - TYPICAL INSTALLATIONS

20HEATING Controlled combustion is the most efficient technique for wood heating because it enables you to select the type of combustion you want for

Page 15 - Clay liner

21RELOADINGOnce you have obtained a good bed of embers, you should reload the unit. In order to do so, open the air controls to maximum a few second

Page 16 - FACTORY BUILT THIMBLE:

22ASH DISPOSAL Ashes should be removed from the stove every few days or when ashes get to 2 to 3 inches deep. Always empty the stove when it is cold

Page 17

23MAINTENANCE Your Drolet stove is a high efficiency stove and therefore require little maintenance. It is important to perform a visual inspection o

Page 18 - OUTSIDE COMBUSTION AIR

1700, rue Léon-Harmel, Québec (Québec) G1N 4R9 tel. : (418) 527-3060 fax : (418) 527-4311 e-mail : [email protected] web site : www.drolet.ca LIMI

Page 19 - WOODSTOVE UTILISATION

2INTRODUCTION SBI INC., one of the most important wood stove and fireplace manufacturers in Canada, congratulates you on your purchase and wishes to

Page 20 - IGNITION

3TECHNICAL SPECIFICATIONS Combustible: Wood Recommended Surface 500 to 1 800 ft2 (46 to 167 m2) Heating Capacity : E.P.A : 30 800 BTU/h (9.02 kW) Ef

Page 21 - HEATING

ASSEMBLY BALTIC Pedestal Base Installation: 1. Slide the front part of the pedestal base around the pedestal and fix the rear part with the two supp

Page 22 - RELOADING

AUSTRAL, AZIMUTH, LEGEND AND MYRIADAsh Pan Installation: 5

Page 23 - ASH DISPOSAL

DOOR ADJUSTMENT In order for your stove to operate properly, the door should be adjusted periodically to provide an air tight fit. To adjust: • Rem

Page 24 - MAINTENANCE

7INSTALLATION SAFETY NOTICE • IF THIS STOVE IS NOT PROPERLY INSTALLED, A HOUSE FIRE MAY RESULT. TO REDUCE THE RISK OF FIRE, FOLLOW THE INSTALLATIO

Page 25 - LIMITED LIFETIME WARRANTY

FLOOR PROTECTOR Your wood stove should be placed on a non-combustible surface with a R value of 1.0. For multiple layers, add R-values of each layer t

Commentaires sur ces manuels

Pas de commentaire